Six emodel three inch housing for installation into existing sheet rock ceilings where access is only available from below the ceiling. For use in non-insulated ceilings, where insulation can be kept 3" from fixtures. Rated for use with a low voltage MR16 or AR111 lamp.
CONSTRUCTION Housing : 0.050 enamel one-piece drawn aluminum housing adjusts to a ceiling thickness from 5/8" to 1-3/8". Housing terminates at a 1/4" ceiling flange for even positioning of housing angle within the ceiling. Structural arm consists of 0.050 steel and connects to housing with j-box and transformer. Integral springs brackets provided.
Clearance : Non-IC housings require a minimum clearance of 3" from thermal insulation and 1/2" from adjacent building components.
Socket : Low voltage bi-pin socket with heat shield. (AR111/PAR38 socket is included with trim)
Mounting : Four high tension tempered steel springs secure remodel housing to ceiling. (Hole cutout template provided for convenience).
Junction Box : Prewired 15 cubic inch 0.060" thick galvanized steel, with six 1/2" knockouts, four Romex® pryouts, and snap on cover. All leads are #18AWG wire, the ground wire is connected to the bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in